AIRAYA AI108 SETUP HACK
Changes maded here are final!
DO NOT use standard web interface after you save these settings!
If you make changes in standart web interface of a hacked bridge - hacked settings will be lost.
Step 1: Login to the bridge using standart web interface. Leave it open.
Step 2: Open this document in new IE window (I rocommend using IE for configuration).
Step 3: Enter here the IP address, mask and gateway of the bridge.
Step 4: Set the channel and output power, you can leave transmit mode to 0.
Step 5: Click Submit and power cycle the bridge to load the new settings.
Step 6: In the 1 minute interval enter in testlink mode (telnet to port 4000, 4001) and choose the best mode (C=1000).
Step 7: Restart the bridge, wait 1 minute and test the network.